Describe the bug and provide the minimal reproduce step
On IoTDB 2.0.8 (Windows, all-bin), three Pipe processor threads concurrently wait tens of seconds for memory to parse sequence TsFiles. At the same time, compaction is running on the same databases. Cross-space compaction then fails while reading an older TsFile: the native FileChannel.read returns Windows error 1450, ERROR_NO_SYSTEM_RESOURCES (系统资源不足,无法完成请求的服务。).
This is not a Java heap OutOfMemoryError. The read fails inside sun.nio.ch.FileDispatcherImpl.read0.
2.0.10 PR #17542 ("Do not stop pipe for Waited for memory to parse TsFile") only keeps the Pipe subtask from stopping on that timeout. It does not address the native read failure under the same concurrent Pipe + compaction load.
What did you expect to see?
Pipe TsFile parsing and compaction should back off when memory or OS read resources are short, instead of three Pipe workers and several compaction tasks reading TsFiles at once until Windows returns ERROR_NO_SYSTEM_RESOURCES.
What did you see instead?
Pipe workers block 20–39 seconds waiting for parse memory and then report temporary OOM. Concurrently, compaction cannot read a TsFile because the OS reports insufficient system resources. The file involved in the failed read (...\11\2952\...) is not one of the files the Pipe workers were parsing (...\11\2959\... and ...\12\2959\...).
Error
2026-09-24 03:51:20,892 [pool-15-IoTDB-Compaction-Schedule-3] ERROR o.a.t.r.r.LocalTsFileInput:88 - 从当前位置读取 D:\apache-iotdb-2.0.8-all-bin\apache-iotdb-2.0.8-all-bin\data\datanode\data\sequence\root.ShipData\11\2952\1785369603984-1-5-2.tsfile 时出错
2026-09-24 03:51:21,229 [pool-15-IoTDB-Compaction-Schedule-3] ERROR o.a.i.d.s.d.c.s.i.RewriteCrossSpaceCompactionSelector:429 - root.ShipData cannot select file for cross space compaction
org.apache.iotdb.db.exception.MergeException: java.io.IOException: 系统资源不足,无法完成请求的服务。
at org.apache.iotdb.db.storageengine.dataregion.compaction.selector.impl.RewriteCrossSpaceCompactionSelector.selectOneTaskResources(RewriteCrossSpaceCompactionSelector.java:153)
at org.apache.iotdb.db.storageengine.dataregion.compaction.selector.impl.RewriteCrossSpaceCompactionSelector.selectCrossSpaceTask(RewriteCrossSpaceCompactionSelector.java:375)
...
Caused by: org.apache.tsfile.exception.NotCompatibleTsFileException: java.io.IOException: 系统资源不足,无法完成请求的服务。
at org.apache.tsfile.read.TsFileSequenceReader.loadFileVersion(TsFileSequenceReader.java:439)
at org.apache.tsfile.read.TsFileSequenceReader.<init>(TsFileSequenceReader.java:316)
...
Caused by: java.io.IOException: 系统资源不足,无法完成请求的服务。
at java.base/sun.nio.ch.FileDispatcherImpl.read0(Native Method)
at java.base/sun.nio.ch.FileDispatcherImpl.read(FileDispatcherImpl.java:60)
at java.base/sun.nio.ch.IOUtil.readIntoNativeBuffer(IOUtil.java:341)
at java.base/sun.nio.ch.IOUtil.read(IOUtil.java:307)
at java.base/sun.nio.ch.IOUtil.read(IOUtil.java:284)
at java.base/sun.nio.ch.FileChannelImpl.implRead(FileChannelImpl.java:251)
at java.base/sun.nio.ch.FileChannelImpl.read(FileChannelImpl.java:231)
at org.apache.tsfile.read.reader.LocalTsFileInput.read(LocalTsFileInput.java:83)
at org.apache.tsfile.read.TsFileSequenceReader.loadFileVersion(TsFileSequenceReader.java:429)
Pipe side, same window:
2026-09-24 03:51:07,196 [pool-48-IoTDB-Pipe-Processor-Executor-Pool-3] INFO o.a.i.d.p.e.c.t.PipeTsFileInsertionEvent:803 - Wait for memory enough for parsing ...\sequence\root.ShipData\11\2959\1789622109110-279-1-0.tsfile for 20.007 seconds.
2026-09-24 03:51:15,768 [pool-48-IoTDB-Pipe-Processor-Executor-Pool-2] INFO o.a.i.d.p.e.c.t.PipeTsFileInsertionEvent:803 - Wait for memory enough for parsing ...\sequence\root.ShipData\12\2959\1789624287446-87-0-0.tsfile for 20.02 seconds.
2026-09-24 03:51:19,501 [pool-48-IoTDB-Pipe-Processor-Executor-Pool-2] WARN o.a.i.c.p.r.l.PipePeriodicalLogReducer:51 - Parse TsFile ...\1789624287446-87-0-0.tsfile error. Because: TimeoutException: Waited 23.753 seconds for memory to parse TsFile
2026-09-24 03:51:25,629 [pool-48-IoTDB-Pipe-Processor-Executor-Pool-1] WARN ... TimeoutException: Waited 25.243 seconds for memory to parse TsFile (...\1789623847592-339-0-0.tsfile)
2026-09-24 03:51:26,256 [pool-48-IoTDB-Pipe-Processor-Executor-Pool-3] WARN ... TimeoutException: Waited 39.067 seconds for memory to parse TsFile (...\1789622109110-279-1-0.tsfile)
Anything else?
Timeline (2026-09-24 03:51)
- Pipe Pool-1, Pool-2, and Pool-3 each log
Wait for memory enough for parsing every 10 seconds, on three different sequence TsFiles (root.ShipData partitions 11 and 12). Waits reach 20–30 seconds.
- Cross-space compaction of
root.ShipData-12 starts (1 seq file + 1 unseq file, about 14.7 MB) and finishes.
- Pipe Pool-2 gives up after 23.753 seconds:
TimeoutException: Waited 23.753 seconds for memory to parse TsFile, then Temporarily out of memory in pipe event processing.
- Unsequence and sequence inner compaction of
root.ShipData-11 start together (5 files / 3 MB and 5 files / 9 MB).
- Cross-space compaction selection for
root.ShipData fails while reading sequence\root.ShipData\11\2952\1785369603984-1-5-2.tsfile. Cause: java.io.IOException: 系统资源不足,无法完成请求的服务。
- The two remaining Pipe workers then time out as well (25.243 s and 39.067 s).
- Inner compaction of
root.ShipData-11 still completes. A JVM compiler replay file replay_pid15624.log was written in this window; hs_err_pid15624.log was not captured.
Are you willing to submit a PR?
Search before asking
Version
On IoTDB 2.0.8 (Windows, all-bin)
Describe the bug and provide the minimal reproduce step
On IoTDB 2.0.8 (Windows, all-bin), three Pipe processor threads concurrently wait tens of seconds for memory to parse sequence TsFiles. At the same time, compaction is running on the same databases. Cross-space compaction then fails while reading an older TsFile: the native
FileChannel.readreturns Windows error 1450,ERROR_NO_SYSTEM_RESOURCES(系统资源不足,无法完成请求的服务。).This is not a Java heap OutOfMemoryError. The read fails inside
sun.nio.ch.FileDispatcherImpl.read0.2.0.10 PR #17542 ("Do not stop pipe for Waited for memory to parse TsFile") only keeps the Pipe subtask from stopping on that timeout. It does not address the native read failure under the same concurrent Pipe + compaction load.
What did you expect to see?
Pipe TsFile parsing and compaction should back off when memory or OS read resources are short, instead of three Pipe workers and several compaction tasks reading TsFiles at once until Windows returns
ERROR_NO_SYSTEM_RESOURCES.What did you see instead?
Pipe workers block 20–39 seconds waiting for parse memory and then report temporary OOM. Concurrently, compaction cannot read a TsFile because the OS reports insufficient system resources. The file involved in the failed read (
...\11\2952\...) is not one of the files the Pipe workers were parsing (...\11\2959\...and...\12\2959\...).Error
Pipe side, same window:
Anything else?
Timeline (2026-09-24 03:51)
Wait for memory enough for parsingevery 10 seconds, on three different sequence TsFiles (root.ShipDatapartitions 11 and 12). Waits reach 20–30 seconds.root.ShipData-12starts (1 seq file + 1 unseq file, about 14.7 MB) and finishes.TimeoutException: Waited 23.753 seconds for memory to parse TsFile, thenTemporarily out of memory in pipe event processing.root.ShipData-11start together (5 files / 3 MB and 5 files / 9 MB).root.ShipDatafails while readingsequence\root.ShipData\11\2952\1785369603984-1-5-2.tsfile. Cause:java.io.IOException: 系统资源不足,无法完成请求的服务。root.ShipData-11still completes. A JVM compiler replay filereplay_pid15624.logwas written in this window;hs_err_pid15624.logwas not captured.Are you willing to submit a PR?